No fee unless we recover compensation for your family Text size 833-4-ASBESTOS (833-427-2378) Free Case Review

Search

15 results for “Union Carbide Corporation”

  1. Company document · Union Carbide documents · 1981

    Share Audit Procedure and Ventilation Inspection and Audit of Lab Hood, Building 522 Recovery Department (1981)

    A Share Audit Procedure form for the Recovery Department's ventilation procedure, dated fourth quarter 1981, with a ventilation inspection and audit checklist for a lab hood in Building 522 Recovery. The audit form marked no deficiency and…

  2. Company document · Union Carbide documents · 1981

    Share Audit Procedure and Ventilation Inspection and Audit of Lab Hood, Building 522 Recovery Department (4Q 1981)

    A Share Audit Procedure form for the Recovery Department's ventilation procedure, dated 4Q 1981, followed by a Ventilation Inspection and Audit checklist for a lab hood in Building 522 Recovery. The form records no deficiency, says the procedure is…

  3. Company document · Union Carbide documents · 1981

    Share Audit Procedure and Hearing Protection, Noise and Ventilation Inspection Forms, Maintenance Department (4Q 1981)

    Set of mostly handwritten-fill audit forms for the Maintenance Department, fourth quarter 1981, covering the ventilation, noise and hearing protection procedure. The summary form records 10 personnel interviewed, no deficiency, and a re-audit set…

  4. Company document · Union Carbide documents · 1981 · page 1

    SHARE Audit of Ventilation, Sanitation and Breathing Air Procedures, Reaction Department (4Q 1981)

    In the document: …YES Should retraining and another audit be conducted? (Es) If yes, when? NO NO 20 19¥ 2 BRE 0174 Union Carbide trial exhibit UC-1815: SHARE Audit of Ventilation, Sanitation and Breathing Air Procedures, Reaction…

  5. Company document · Union Carbide documents · page 1

    Share Audit Procedure Form for Sanitation Procedure, Employee Relations Department (4Q 1981)

    In the document: …explain. Should retraining and another audit be conducted? If yes, when? 67 Q YES (#55) NO )9F2 BRE 0196 Union Carbide trial exhibit UC-1820: Share Audit Procedure Form for Sanitation Procedure, Employee Relations De…

  6. Company document · Union Carbide documents · 1981 · page 1

    Share Audit Procedure Form for Laboratory Ventilation Procedure (1981)

    In the document: …YES NO If YES, explain, Should retraining and another —— audit be conducted? If yes, when? 24 (xs) NO 1982 BRE 0197 Union Carbide trial exhibit UC-1821: Share Audit Procedure Form for Laboratory Ventilation Procedure (1981)

  7. Company document · Union Carbide documents · 1981 · page 1

    Share Audit Procedure and Detector Tube Inspection and Audit, Distribution Department (4Q 1981)

    In the document: …explain, YES Should retraining and another audit be conducted? 5) ) If yes, when? 4 @ NO 1982 BRE 0213 Union Carbide trial exhibit UC-1825: Share Audit Procedure and Detector Tube Inspection and Audit, Distribution D…

  8. Company document · Union Carbide documents · 1981 · page 1

    Share Audit Procedure Form for Maintenance Department Asbestos Handling Procedure (1981)

    In the document: …explain. YES NO Should retraining and another audit be conducted? YES NO If yes, when? AS REQUIR ED BRE 0171 Union Carbide trial exhibit UC-1741: Share Audit Procedure Form for Maintenance Department Asbestos Handling…

  9. Company document · Union Carbide documents · April 6, 1981 · page 1

    Share Audit Procedure and Noise and Hearing Protection Inspection Audit Forms, Energy/Oxygen Department (1981)

    In the document: …retraining and another audit be conducted? If yes, when? | JN YES }9 YES NO MONTAS BRE 0379 Union Carbide trial exhibit UC-1869: Share Audit Procedure and Noise and Hearing Protection Inspection Audit For…

  10. Company document · Union Carbide documents · page 1

    Share Audit Procedure Blank Form (undated)

    In the document: …6 months? (If appropriate) Should existing procedure be modified? If YES, explain, Should retraining and another audit be conducted? - If yes, when? BRE 0306 Union Carbide trial exhibit UC-1837: Share Audit Procedure Blank Form (undated)

  11. Company document · Union Carbide documents · April 30, 1982 · page 1

    SHARE Audit Procedure Form for Maintenance Department on Ventilation, Asbestos, Radiation and Chemicals (1982)

    In the document: …and another audit be conducted? _—— If yes, when? b Lea MONTAS % see ChEMIcAL SysTEM INVENTORY AUDIT SAEET BRE 0157 Union Carbide trial exhibit UC-1739: SHARE Audit Procedure Form for Maintenance Department on Ventilation, As…

  12. Company document · Union Carbide documents · March 25, 1981 · page 1

    Share Audit Procedure Form for Maintenance Department on Proper Handling and Disposal of Asbestos (1981)

    In the document: …If yes, when? YES YES Should existing procedure be modified? If YES, explain. NO NO As Required BRE 0187 Union Carbide trial exhibit UC-1818: Share Audit Procedure Form for Maintenance Department on Proper Handling…

  13. Company document · Union Carbide documents · 1981 · page 1

    Ventilation Inspection and Audit of Laboratory 422 Lab Hoods, with SHARE Audit Procedure Sheet (1981)

    In the document: …other clutter kept to a minimun. 4. Drainage is toward sink. IN INN VI HOUSEKEEPING BRE 0198 Union Carbide trial exhibit UC-1822: Ventilation Inspection and Audit of Laboratory 422 Lab Hoods, with SHARE Au…

  14. Company document · Union Carbide documents · 1981 · page 1

    Share Audit Procedure and Ventilation Inspection and Audit of Laboratory Lab Hoods, Building 422 (1981)

    In the document: …YES . Should retraining and another audit be conducted? If yes, when? YES (crs) NO 19S 2 BRE 0181 Union Carbide trial exhibit UC-1816: Share Audit Procedure and Ventilation Inspection and Audit of Laboratory Lab…

  15. Company document · Union Carbide documents · 1981 · page 1

    Share Audit Procedure Checklists for Maintenance: Ventilation, Noise and Hearing Protection (1981)

    In the document: …If YES, explain. @) Should retraining and another audit be conducted? If yes, when? 2M NO IG¥2Q 1 BRE 0207 Union Carbide trial exhibit UC-1824: Share Audit Procedure Checklists for Maintenance: Ventilation, Noise and Hea…